Aussie Trim – QLD

  • Australian made
  • 15 Year Warranty
  • Delivery QLD & northern NSW
Aussie Panels patio patio in a garden setting in NSW
An oasis in the Aussie heat

AUSSIE TRIM

50mm – 200mm Insulated Roofing Panel
Price List (QLD)

At Aussie Panels, we don’t believe in hidden prices. Our fully itemised quotes let you see products, quantities and prices upfront. Whether you are a licensed builder or a DIYer, you’ll get transparent pricing and honest service across QLD.

50mm
Most Popular

$84

75mm

$88

100mm

$91

125mm

$95

150mm

$98

200mm

$106

All prices include GST. Panels are 1m wide, so the lineal metre (LM) price is also the price per m². Prices current as of September 2026.

Insulated Trim or Ribbed panel in Surfmist
Aussie Trim – Surfmist® Off White


What is an insulated roofing panel?

Engineered for strength and built for speed, Aussie Trim delivers longer spans and a faster build — without compromising on protection.

  • Longer panel spans thanks to a higher rib height, for increased strength and fewer support posts
  • Wide 1000mm panels mean faster installation with fewer, less visible joins
  • 3-in-1 finished product: roof, insulation, ceiling
  • Insulation core made from Fire-Retardant EPS (Expanded Polystyrene) for added safety
  • BAL-40 bushfire rating for peace of mind in bushfire-prone areas
House roof 2
Aussie Panels Freestanding pool cabana

How are we different?

Beyond performance, Aussie Trim brings a clean, contemporary finish that blurs the line between indoor and outdoor living.

  • Smooth ceiling finish that extends your living space seamlessly from inside to out
  • Reduces radiant heat and absorbs noise, for a cooler, quieter space
  • High-quality pre-painted steel in a range of contemporary colours

What’s In A Patio or Carport Kit?

Your fully itemised quote will detail product lengths and quantities
Kits include:
Insulated Panels
Flashings
Gutter
Beams
Posts
Fixings
Receiver Channel (Attached)
Extenda Brackets (Flyovers)

Delete anything you don’t want
e.g. remove posts or beams from the quote

Add something extra e.g. silicone or concrete


Pickup

8 Andrew Campbell Dr, Narangba QLD 4504
Opening Hours
Mon-Fri: 8am – 2pm
Sat: 7am – 9am Sun: Closed


QLD – 19 Roof Colours including Dover White® (Alpine White)


QLD – Ceiling Options

Aussie Panels Smooth Ceiling Profile in NSW
Smooth in Surfmist® or Thredro White® – Standard
Aussie Panels Attached Patio QLD
Aussie Panels Attached Patio

Marine Plus 5-Layer Protection

Engineered for coastal areas and locations near water — including pools — Marine Plus guards against premature steel deterioration with a robust 5-layer finish.

All that protection is backed by a 15-year site-specific warranty.

Marine Plus protection logo

Marine Plus Colours: Panel Roof, Flashings, Gutters

Marine Plus Colours: Panel Ceiling, Beams


  • Google logo

    Great to deal with and super helpful and excellent service, communication is really good and great turnaround from ordering. Good quality panels and trims. What you see is what you get and you won’t beat their prices.  very thorough. Definitely worth a call for your next job.
    Jake
    Builder
  • Google logo


    The service and knowledge from Aussie panels has been excellent. Prompt quotes and invoicing and minimal back and forth required. Products show up on time, and are of good quality. Had to make a call to them on delivery day, office staff were pleasant and helpful as well as the delivery driver. Hard to get service like this with trade suppliers. Will continue getting products from Aussie Panels.
    Terry
    Builder
  • Google logo

    The staff at Aussi Panels could not be more helpful! They’re efficient and polite, providing an unrivalled service. I shopped around and other competitors didn’t have enough product knowledge to help me with the questions I had.
    Brendan Ross
    Home Owner

Frequently Asked Questions

Sketch of Trim (Ribbed) Profile
Trim (Ribbed) Profile

Aussie Trim is manufactured to strict industrial standards using high-grade components. Each panel provides an effective coverage width of 1000mm (1 metre) when joined together on-site and is cut to your exact custom lengths (minimum length 1.8m).

The exterior top skin consists of a heavy-duty 0.42mm thickness steel sheet rolled into a structural ribbed profile (AZ150 G550), while the interior ceiling underside is a rigid 0.60mm thickness flat, smooth steel skin (AZ150 G300). The layers are continuously bonded to a fire-retardant insulation core using a thermosetting, CFC-free two-part polyurethane adhesive. The final exterior layer features an architectural 25% gloss paint coat compliant with AS/NZS 2728 and AS 1397 standards.

Aussie Trim – Screw Chart

To comply with verified engineering certification guidelines, Aussie Trim panels must be fixed using a minimum of 4 structural fasteners per panel, per supporting beam. All primary fasteners must be high-quality Class 4 Climaseal coated and fitted with an approved cyclonic sealing washer. Select your fastener lengths based on your framing material and panel thickness:

  • 50mm Panels: Use Tek 14×125 screws for metal framing, or Type 17 14×125 screws for timber framing.
  • 75mm Panels: Use Tek 14×150 screws for metal framing, or Type 17 14×150 screws for timber framing.
  • 100mm Panels: Use Tek 14×175 screws for metal framing, or Type 17 14×200 screws for timber framing.
  • 125mm Panels: Use Tek 14×200 screws for metal framing, or Type 17 14×200 screws for timber framing.
  • 150mm Panels: Use Tek 14×225 screws for metal framing, or Type 17 14×250 screws for timber framing.
  • 175mm Panels: Use Tek 14×250 screws for metal framing, or Type 17 14×250 screws for timber framing.
  • 200mm Panels: Use Tek 14×275 screws for metal framing, or Type 17 14×275 screws for timber framing.
  • Overlaps: Secure side laps and overlaps at maximum 900mm centres using Tek 12×20 stitching screws to ensure a weather-tight seal.

The total weight of your Aussie Trim roof panels depends directly on your selected core insulation thickness parameters:

50mm Core Insulation: Statically weighs 10.58 kg/m²

75mm Core Insulation: Statically weighs 10.94 kg/m²

100mm Core Insulation: Statically weighs 11.37 kg/m²

125mm Core Insulation: Statically weighs 11.80 kg/m²

150mm Core Insulation: Statically weighs 12.23 kg/m²

(Weight metrics for 175mm and 200mm configurations can be provided by our team based on your specific custom layout requirements).

Aussie Trim panels provide outstanding thermal efficiency and noise reduction, helping home extensions, carports, and patios stay comfortable year-round. Thermal resistance performance changes slightly based on ambient temperatures and foam core thickness parameters:

  • 50mm Panels: Delivers an R-Value of 1.61 at 8°C ambient temperature, and 1.59 at 20°C.
  • 75mm Panels: Delivers an R-Value of 2.26 at 8°C ambient temperature, and 2.22 at 20°C.
  • 100mm Panels: Delivers an R-Value of 2.66 at 8°C ambient temperature, and 2.59 at 20°C.
  • 125mm Panels: Delivers an R-Value of 3.25 at 8°C ambient temperature, and 3.17 at 20°C.
  • 150mm Panels: Delivers an R-Value of 3.94 at 8°C ambient temperature, and 3.75 at 20°C.
  • 200mm Panels: Delivers an R-Value of 4.85 at 8°C ambient temperature, and 3.75 at 20°C.

The total combined thickness of the finished panel includes the inner insulation foam layer plus the height of the outer protective roof ribs:

  • 50mm Core Panels: Feature a total overall thickness of 78mm.
  • 75mm Core Panels: Feature a total overall thickness of 103mm.
  • 100mm Core Panels: Feature a total overall thickness of 128mm.
  • 125mm Core Panels: Feature a total overall thickness of 153mm.
  • 150mm Core Panels: Feature a total overall thickness of 178mm.
  • 175mm Core Panels: Feature a total overall thickness of 203mm.
  • 200mm Core Panels: Feature a total overall thickness of 228mm.

Thanks to the deep profile drainage channels and advanced structural ribs, Aussie Trim can be safely installed at an ultra-low minimum roof pitch of just 2° (which equals a minor 35mm drop per linear metre of run). This makes it an ideal solution for low-profile carports and seamless flyover patio extensions.

Below is a guide for working out the lay for Aussie Trim Roof Panels. Always start from a corner or the prevailing wind side.

Drawings of Roof Lay (cutback) Direction

To streamline construction times on-site, panels are manufactured with a standard 60mm factory pre-cut rebate on the Right-Hand (RH) gutter profile end to accept your fascia receiving channel. Custom RH installation rebates of 80mm, 100mm, and 120mm can be cut during production on request. Left-Hand (LH) rebates are available at a fixed 60mm width; please note that the steel ceiling skin is removed during this process, and the installer will simply clear the remaining foam core during assembly.

Aussie Trim is fully accredited, BCA compliant, and CodeMark™ Certified (Certificate Number: CM40104). The insulation center is rolled from high-quality SL Grade fire-retardant expanded polystyrene (EPS-FR). Tested under rigorous AS/NZS 1530.3 criteria, the systems are fully certified for use in high-risk BAL-40 Bushfire Attack Level zones. To satisfy local certification requirements, remember to specify our matching BAL-40 edge flashings to fully cover the exposed core ends during your quote request.

Our entire inventory is specifically engineered to maximize open outdoor spans with fewer support columns. Structural strength thresholds are calculated using a deflection limit of span 1/150 in strict accordance with Serviceability Limit State criteria per AS1170.0 (TABLE C1). The calculations safely allow for a uniform dead load up to 25 kg/m² to accept light and fan fittings, a distributed live load capacity of 0.25kPa, and a concentrated non-trafficable maintenance load up to 140kg (exceeding min. requirements of AS/NZS 1170.1:2001).


Important Project Notes: Aussie Panels provides material take-off estimations and quantity assessments as a commercial project guide only; the executing contractor, building site installer, or independent certifier must manually verify the final Bill of Materials (BOM) for accuracy prior to distribution. It remains the absolute legal responsibility of the project installer to ensure that any existing structure or foundation to which these panels are fixed has sufficient load-bearing capabilities. We recommend displaying standard caution and safety signage across finished installations.